Free · No sign-up · 25 questions · Updated November 10, 2026
Free RHS practice test: 25 questions with answers
A free 25-question practice test for the DANB Radiation Health and Safety (RHS) exam, with the answer and a plain-English explanation for every question. It covers radiation safety, technique and errors, digital receptors, panoramic positioning and infection control.
How this test is built
- Weighted like DANB’s outline: Purpose and technique (50%), Radiation safety (25%), Infection control (25%).
- The real exam has 75 questions in 60 minutes. For the same pace, give yourself about 20 minutes for these 25.
- Pick your answer, then open “Show answer” to check it and read why.
These are original RHS-style questions written by Accelerated Assisting, not questions from DANB. New to the exam? Read the exam guide first.
Question 1 · Radiation safety
What does the ALARA principle ask every operator to do?
- A.Always Leave A Receptor Available for retakes
- B.Keep radiation exposure As Low As Reasonably Achievable
- C.Use the Approved Limit for Adult Radiographs on every patient
- D.Avoid all radiographs unless the patient is in pain
Show answer
Answer: B. Keep radiation exposure As Low As Reasonably Achievable
ALARA means as low as reasonably achievable. Every exposure should be justified, and the operator uses every reasonable method (fast receptors, rectangular collimation, correct technique, no unnecessary retakes) to keep the dose down.
Question 2 · Radiation safety
What does a personnel dosimeter badge measure?
- A.The dose the patient received from each exposure
- B.Whether the X-ray unit is leaking radiation from the tubehead
- C.The radiation the person wearing it has been exposed to on the job
- D.How long the exposure button was held down
Show answer
Answer: C. The radiation the person wearing it has been exposed to on the job
A dosimeter records the occupational exposure of the person who wears it. It is worn at work only and returned for reading on schedule. It does not measure patient dose.
Question 3 · Radiation safety
What is the maximum permissible whole-body dose per year for a person who is occupationally exposed to radiation?
- A.0.05 rem (0.5 mSv)
- B.0.5 rem (5 mSv)
- C.5 rem (50 mSv)
- D.50 rem (500 mSv)
Show answer
Answer: C. 5 rem (50 mSv)
The maximum permissible dose for occupationally exposed workers is 5 rem (50 mSv) per year. Following ALARA, a dental assistant using correct technique should receive a tiny fraction of that.
Question 4 · Radiation safety
Which change does the most to reduce the patient's exposure on an intraoral image?
- A.Switching from a round to a rectangular collimator
- B.Turning the room lights off during the exposure
- C.Using a longer exposure time with a lower kVp
- D.Placing the thyroid collar after the exposure
Show answer
Answer: A. Switching from a round to a rectangular collimator
A rectangular collimator restricts the beam to about the size of the receptor, so less tissue is exposed than with a round beam. It is one of the most effective ways to reduce patient dose.
Question 5 · Radiation safety
What does the aluminum filter in the tubehead do?
- A.Focuses the beam onto the receptor
- B.Removes low-energy X-rays that would be absorbed by the patient without helping the image
- C.Cools the tube between exposures
- D.Changes the beam from round to rectangular
Show answer
Answer: B. Removes low-energy X-rays that would be absorbed by the patient without helping the image
Filtration absorbs the weak, long-wavelength X-rays. They cannot reach the receptor to form an image, so letting them through would only add to the patient's dose.
Question 6 · Radiation safety
When is a thyroid collar usually NOT used?
- A.Bitewing images on an adult
- B.Periapical images on a child
- C.Panoramic images, because it can block part of the image
- D.Occlusal images of the maxilla
Show answer
Answer: C. Panoramic images, because it can block part of the image
A thyroid collar is recommended for intraoral images, especially for children. On a panoramic image it can block the beam and hide anatomy, which would mean a retake and more exposure.
Question 7 · Radiation safety
If you double your distance from the X-ray source, what happens to the intensity of the radiation reaching you?
- A.It is cut in half
- B.It drops to one quarter
- C.It stays the same
- D.It doubles
Show answer
Answer: B. It drops to one quarter
The inverse square law: intensity changes with the square of the distance. Twice the distance gives one quarter of the intensity. That is why distance is one of the operator's best protections.
Question 8 · Purpose and technique
A periapical image shows the teeth stretched out, longer than they really are. What usually causes this?
- A.Too little vertical angulation
- B.Too much vertical angulation
- C.Incorrect horizontal angulation
- D.The patient moved during the exposure
Show answer
Answer: A. Too little vertical angulation
Too little vertical angulation causes elongation. Too much vertical angulation causes foreshortening, where the teeth look too short. Horizontal angulation errors cause overlapped contacts instead.
Question 9 · Purpose and technique
On a bitewing, the contacts between the premolars overlap. Which error caused it?
- A.Incorrect vertical angulation
- B.Incorrect horizontal angulation
- C.The receptor was placed backward
- D.The exposure time was too short
Show answer
Answer: B. Incorrect horizontal angulation
The beam must pass straight through the contacts. If the horizontal angle is off, the teeth are projected over each other and the contacts overlap, which can hide interproximal caries.
Question 10 · Purpose and technique
Part of the image is completely blank, with a sharp curved or straight edge. What happened?
- A.The patient's tongue was in the way
- B.The image was overexposed
- C.A cone cut: the beam was not centered over the receptor
- D.The sensor cable was bent
Show answer
Answer: C. A cone cut: the beam was not centered over the receptor
A cone cut happens when the position indicating device (PID) is not centered over the receptor, so part of the receptor gets no X-rays. The edge is curved with a round PID and straight with a rectangular one.
Question 11 · Purpose and technique
What are bitewing images mainly used to check?
- A.The apex of each tooth and the bone around it
- B.Interproximal caries and the height of the crestal bone
- C.The whole jaw, including the TMJ
- D.Impacted third molars
Show answer
Answer: B. Interproximal caries and the height of the crestal bone
Bitewings show the crowns of the upper and lower teeth and the crestal bone together. They are the main image for finding caries between teeth and checking bone levels.
Question 12 · Purpose and technique
A periapical image must show what, at minimum?
- A.Only the crowns of the teeth
- B.The whole tooth, including the apex, and some of the bone around it
- C.Both arches on one image
- D.The maxillary sinus and the nasal cavity
Show answer
Answer: B. The whole tooth, including the apex, and some of the bone around it
"Peri" means around and "apical" refers to the apex. A diagnostic periapical shows the entire tooth from crown to root tip, plus a few millimeters of bone beyond the apex.
Question 13 · Purpose and technique
With labial mounting, how do you view the images?
- A.As if you were inside the patient's mouth looking out
- B.As if you were facing the patient, so the patient's left is on your right
- C.With all maxillary images on the bottom row
- D.In the order they were exposed
Show answer
Answer: B. As if you were facing the patient, so the patient's left is on your right
Labial mounting is the method recommended by the ADA: you view the images as if you are facing the patient. The patient's left side appears on your right.
Question 14 · Purpose and technique
On a panoramic image the occlusal plane is flat or turned down at the ends (a "frown"), and the hard palate overlaps the maxillary roots. What positioning error causes this?
- A.The chin was tipped too far down
- B.The chin was tipped too far up
- C.The patient was too far back in the focal trough
- D.The patient did not close on the bite block
Show answer
Answer: B. The chin was tipped too far up
Chin up flattens or reverses the smile line and pushes the hard palate down over the maxillary roots. Chin down exaggerates the smile and crowds the lower anterior teeth.
Question 15 · Purpose and technique
A blurry, larger copy of a hoop earring appears on the opposite side of a panoramic image. What is it?
- A.A double exposure
- B.A ghost image, because the earring was left on
- C.A processing artifact from the sensor
- D.Normal anatomy, the hyoid bone
Show answer
Answer: B. A ghost image, because the earring was left on
Metal left on the patient creates a ghost image on the opposite side, higher and larger than the real object. Remove earrings, necklaces, piercings, glasses and removable appliances before a pano.
Question 16 · Purpose and technique
A digital image comes out much too dark. Which is the most likely cause?
- A.The exposure time was too long
- B.The exposure time was too short
- C.The receptor was too small
- D.The patient was wearing a lead apron
Show answer
Answer: A. The exposure time was too long
Too much exposure (time or mA too high) makes the image too dark. Too little makes it too light and grainy. Use the settings recommended for the receptor and the patient's size.
Question 17 · Purpose and technique
Which of these appears radiopaque (light) on a dental image?
- A.The pulp chamber
- B.An amalgam restoration
- C.A carious lesion
- D.Air in the pharynx
Show answer
Answer: B. An amalgam restoration
Radiopaque structures stop X-rays and look white or light: metal restorations, enamel and dense bone. Radiolucent structures let X-rays through and look dark: the pulp, caries and air spaces.
Question 18 · Purpose and technique
A small round radiolucency appears near the apices of the mandibular premolars. Which normal landmark is it most likely to be?
- A.The mental foramen
- B.The incisive foramen
- C.The maxillary sinus
- D.The genial tubercles
Show answer
Answer: A. The mental foramen
The mental foramen sits near the apices of the mandibular premolars and can be mistaken for a lesion at the root tip. The incisive foramen is between the maxillary central incisors.
Question 19 · Purpose and technique
Which digital receptor has to be scanned by a separate reader after the exposure before the image appears?
- A.A CMOS sensor
- B.A CCD sensor
- C.A phosphor storage plate (PSP)
- D.None of them; all digital images appear instantly
Show answer
Answer: C. A phosphor storage plate (PSP)
A PSP plate stores the image and must be scanned to see it, then erased before reuse. Wired or wireless CCD and CMOS sensors send the image to the computer right away.
Question 20 · Purpose and technique
Why use a receptor-holding device with an aiming ring for the paralleling technique?
- A.It lets the operator skip the lead apron
- B.It helps align the beam with the receptor, which reduces cone cuts and angulation errors
- C.It makes the exposure shorter
- D.It replaces the need for a rectangular collimator
Show answer
Answer: B. It helps align the beam with the receptor, which reduces cone cuts and angulation errors
The aiming ring shows where to place the PID so the beam is centered on and perpendicular to the receptor. That prevents cone cuts and angulation errors and so reduces retakes.
Question 21 · Infection control
Under the Spaulding classification, a digital sensor that goes in the patient's mouth is which kind of item?
- A.Critical
- B.Semicritical
- C.Noncritical
- D.Housekeeping
Show answer
Answer: B. Semicritical
Items that touch mucous membranes but do not penetrate tissue are semicritical. Sensors can't be heat-sterilized, so they are covered with an FDA-cleared barrier and then cleaned and disinfected.
Question 22 · Infection control
How should a heat-tolerant receptor-holding device be processed between patients?
- A.Wipe it with a surface disinfectant
- B.Rinse it under running water
- C.Clean it, then heat-sterilize it
- D.Store it in a drawer until the end of the day
Show answer
Answer: C. Clean it, then heat-sterilize it
Receptor holders contact mucous membranes, so they are semicritical. If they tolerate heat, clean them and heat-sterilize them. Single-use holders are thrown away.
Question 23 · Infection control
After exposing a PSP plate in a barrier envelope, what is the correct way to get the plate out for scanning?
- A.Remove your gloves, then tear the envelope open with bare hands
- B.Open the envelope with gloved hands and let the plate drop onto a clean surface without touching it
- C.Spray the envelope with disinfectant and scan it with the envelope on
- D.Rinse the envelope under water and dry it with a towel
Show answer
Answer: B. Open the envelope with gloved hands and let the plate drop onto a clean surface without touching it
The outside of the envelope is contaminated with saliva. Open it with gloved hands and drop the plate onto a clean surface without touching it. Then remove gloves, perform hand hygiene and handle the plate with clean hands.
Question 24 · Infection control
You touched the tubehead, the PID and the exposure button with gloved hands. What do those surfaces need between patients?
- A.Nothing; X-rays sterilize the equipment
- B.Barriers changed between patients, or cleaning and disinfection
- C.Heat sterilization
- D.Only a dry paper towel
Show answer
Answer: B. Barriers changed between patients, or cleaning and disinfection
They are clinical contact surfaces. Cover them with barriers and change the barriers between patients, or clean and disinfect them with an EPA-registered hospital disinfectant. Radiation does not disinfect anything.
Question 25 · Infection control
When should the operator perform hand hygiene during a radiographic procedure?
- A.Only if the gloves tear
- B.Before putting on gloves and after removing them
- C.Only at the end of the day
- D.Gloves make hand hygiene unnecessary
Show answer
Answer: B. Before putting on gloves and after removing them
Gloves can have tiny defects and hands get contaminated when gloves come off. Clean your hands before gloving and again right after removing gloves, for every patient.
Ready for the full-length version?
RHS Prep has 500+ practice questions with explanations, 4 practice exams, a timed 75-question simulator scored by domain, 16 interactive simulations and a study plan built from your exam date. Taught by a practicing dentist, with a pass guarantee.
DANB® is a registered trademark of the Dental Assisting National Board, Inc. This practice test and our courses are not affiliated with or endorsed by DANB.